The camera writes the bill
Owners in San Juan Capistrano usually ask about a liner after something else has gone wrong: an inspector's note in a sale file, an insert they want to buy, a gas water heater that a plumber says is venting into a cracked flue. The price question comes first. Our honest answer is that the number depends on what the inside of the flue looks like, and nobody knows that until a camera has been lowered down it.
Beckham Chimney Experts works from the flue outward. We run the camera, watch the tile seams go past on the screen, and write the liner scope from that footage. This post sets out what goes into that scope, which figures we publish, and which ones we only give after seeing your chimney.
What the footage tells us
A clay tile flue is a stack of short square or oblong sections set on mortar. On the screen, a healthy one looks like a tidy tunnel: even joints, a dull film of soot, no daylight showing through. The faults we find in south Orange County chimneys tend to fall into a few groups:
- Cracked tiles. A hairline running up one face of a section, or a corner that has split off. Very hot fires and the shaking from past quakes both cause it.
- Open joints. The mortar between sections has washed or burned out, leaving a gap where smoke and heat can reach the brick and any wood near it.
- Offsets. One section has slid sideways off the one below, so the tunnel steps. Stacks that rode out the 1994 quake often show this.
- No tile at all. Some older chimneys have bare brick inside, or tile only partway up.
- Wrong size. The tile is sound, but far too large or too small for the appliance it now serves.
Each of these points toward a liner, and each changes the size of the job.
What decides the price
A liner scope from us is built from a short list of measurements and choices. None of them can be pinned down from the street.
- Height. The liner runs from the appliance or smoke chamber to the top of the stack. A one storey ranch in Mission Viejo needs far less pipe than a two storey house with the chimney climbing past a bedroom.
- Diameter. The appliance sets it. An insert, a stove or a gas heater each has a listed outlet size, and the liner matches that, not the old tile.
- Pipe type. Flexible stainless suits flues with a bend or an offset. Rigid sections go into straight runs. The fuel decides the alloy.
- Insulation. Where the old flue has open joints or the chimney sits tight to framing, the liner is wrapped or packed so the outside stays cooler.
- The bottom connection. A tee for a stove, an adapter for an insert, a connector for a gas appliance. Some smoke chambers need work before the pipe can pass.
- The top. A plate seals the old flue around the liner, and a cap goes over it.
- Roof access. Steep clay tile roofs, common on Spanish style houses around town, take more setup than a low shingle roof.
Tell us what the liner will serve and how many storeys the chimney climbs, and we will book the camera visit that turns those items into a written figure.
Figures we publish, and the ones we hold back
Some parts of a liner project have a set price on this site. Others hang on the footage, so we leave them off until we have seen it.
| Item | Our figure |
|---|---|
| Camera inspection, written up with stills | $370 |
| Visual check of the reachable parts | $160 |
| Sweeping ahead of the liner | from $400 |
| Gas insert with its venting, fitted to your present firebox | $2,650 to $5,300 |
| Liner on its own | priced from your footage |
A cap over the new liner is quoted after we measure the flue.
The liner for a wood stove, a pellet unit or a water heater has no published figure. Once the scan is done, you get it in writing with each of the items above broken out, so you can see where the money goes.
Why the scan comes before the figure
A liner priced without a scan is a guess. If the flue turns out to have an offset halfway up, flexible pipe may be needed where rigid was planned. If tiles have fallen in, the debris has to come out before anything else can go down. If the smoke chamber was badly built, it may need parging before the liner can connect. All of those turn up on video and none of them show from the roof.
NFPA 211 asks for the camera inspection whenever the fuel or the appliance changes, so anyone adding an insert or switching from wood to gas needs a Level 2 anyway. We plan the liner from that same footage, so you are not paying for two visits.
What you get after the visit
You receive the video, stills of each fault with its depth from the top, and a written scope. The scope names the diameter, the pipe type, the length, the insulation, what happens at the bottom and the top, and the price. If the flue is sound and only needs sweeping, the report says that too.
The report goes to you, and to anyone else you name when booking: a buyer's agent, an insert dealer, or a plumber who needs to know the vent is sorted.
Local conditions that shape the plan
In San Juan Capistrano and San Clemente the marine layer pushes damp, salty air inland most mornings, so caps and top plates are stainless. Further inland, in Laguna Niguel and Mission Viejo, many houses from the 1970s and 1980s have factory-built fireplaces with a metal flue inside a wood chase. Those are relined or replaced with parts listed for that system, which is a different job from a masonry reline and is priced separately.
Read more on our liner installation page, or see whether a cracked flue needs a reline or a rebuild.
Next
A liner price you can trust starts with footage of your own flue. Use the contact page to set up the scan, and the written figure follows from what it shows.
See the Flue Before You Decide
Beckham Chimney Experts sends a camera up the full run, writes up each fault with stills and prices every fix on its own line. We work from San Juan Capistrano across San Clemente, Laguna Niguel, Mission Viejo and nearby Orange County cities.