Professional chimney service
Beckham Chimney Experts

Stainless Liners Sized to the Appliance Below Your San Juan Capistrano Chimney

Is This the Right Job?

Camera Stills in Every Report
Flue Faults Listed First
Written Quote Before Work
Based in San Juan Capistrano
Camera Stills in Every Report
Flue Faults Listed First
Written Quote Before Work
Based in San Juan Capistrano

What We Do on a Chimney Liner Installation Job

Clay flue tile cracks with heat and quakes, and an insert or gas appliance usually needs a narrower flue than the original. A stainless liner answers both. We film the tile, work out the diameter the appliance needs and install one continuous run from the appliance collar to the crown. Insulation is added where the gap to framing is tight. You keep both camera recordings, the old tile and the new pipe.

Tile filmed before a diameter is chosen
Diameter worked out from the appliance
One continuous run, collar to crown
Insulation where framing sits close
Recordings of old tile and new pipe

What a Liner Does, and When a Flue Needs One

A chimney's real work happens inside the flue, the channel that carries exhaust from the fire to the sky. In older masonry chimneys around San Juan Capistrano, that channel is a stack of clay tiles set in mortar. It works well when it is sound and when the fire below it is the one it was built for. Two things change that. The first is damage. A chimney fire, a quake, or years of rain through an open top crack tiles and wash out the joints between them, and the camera shows gaps where smoke and heat can reach the brick and nearby framing. The second is a change of appliance. Swap the open fire for a closed unit of any fuel and the exhaust shrinks in volume and drops in temperature. Sent up a big clay flue, it slows, cools and condenses, eating the mortar and coating the tile. In both cases a stainless liner gives the appliance a sealed, right-sized path to the top.

We size the liner from the appliance, not from the chimney. Inserts and gas appliances list the flue diameter they need, and wood fireplaces are sized against their opening. The camera run then tells us whether that size will pass. Bends and offsets in the tile column may call for a flexible liner, and a tile narrower than the round liner may call for an oval one. The run's height and shape decide the length and how it will be fed. Where the liner sits close to wood framing, or where the appliance maker requires it, the liner gets an insulating jacket; it holds heat inside the steel, so the framing stays at a safe temperature and the exhaust stays buoyant on the way up. Down at the appliance the liner meets a fitting built for that outlet, and at the crown it passes through a sealed steel plate under a meshed cap.

The Install and the Written Quote

On install day, the fireplace is sealed off, and anything in the throat that blocks the path, often the old damper plate, is removed. From the roof, the liner is lowered down the flue, guided round any offsets, and checked to be sure it is not snagging on a broken tile. At the bottom it is connected to the insert, stove or gas appliance, or for an open fireplace to a fitting that seals to the smoke chamber. Up top, a stainless plate is cut to the crown and sealed, the liner is clamped through it, and the cap goes on. Then the camera goes down the new liner to check the joints and the connection, and the appliance is run to confirm the draft. You get notes on the liner's type, diameter and length, which a future sweep or inspector will need. Homes near the coast in San Clemente get a cap and plate chosen for salt air.

A liner figure needs two inputs, the footage and the appliance model, so it is written up once we have both. The quote names the liner type and diameter, the length, the insulation, the connector and the cap, and lists any repairs that should come first, such as a crumbling crown or a smoke chamber full of gaps. If the liner is part of an insert install, it is priced inside that job. For a gas unit placed in a working fireplace, our installed price, liner included, is $2,650 to $5,300. Homes in San Juan Capistrano, Mission Viejo and Laguna Niguel with tall two-story chimneys or tile roofs need more setup, and that is shown on its own line. On the form, name the fireplace or appliance below the flue and anything you plan to swap in.

How Beckham Chimney Experts Handles the Work

Flue Looked At First

We check the passage before quoting the fix

Stills You Can Keep

Camera frames go into the written report

Line by Line Prices

Each fix has its own figure on the quote

Film After the Work

Liners and rebuilds get a second camera pass

Cities with a Chimney Liner Installation page

Search for your city below. Focus cities open a page about this job there; the rest open the city overview.

All cities

Nothing on the list under that name. Check the spelling or search for the city next door.

More from the service list

Chimney Sweep

Brushing and vacuuming a sooty flue, with the tile run noted so a later camera visit or liner job starts from facts.

Open the page

Chimney Inspection

Level 1 look at flue, crown, damper and firebox, answering whether the chimney suits the fire or appliance it serves.

Open the page

Chimney Repair

Fixes for the parts of a chimney that carry smoke and shed water, ordered from the flue outward.

Open the page

Fireplace Inspection

Room-side check of firebox, damper, hearth and surround, plus the opening sizes an insert or log set would need.

Open the page

Fireplace Repair

Firebox, damper and hearth work on masonry and factory-built units, so the fire burns where it should and smoke goes up.

Open the page

Chimney Level 2 Inspection

Recorded camera pass through the full flue, the level asked for at a sale, a fuel change, or after a quake or flue fire.

Open the page

Chimney Cap Installation

A fitted metal top with mesh sides, sized to one flue or the whole crown, keeping weather and animals out.

Open the page

Chimney Flashing Repair

New metal at the roof line where shingles or tile meet brick, lapped so rain runs past the chimney rather than into it.

Open the page

Chimney Masonry Repair

Brick and joint repair on the outside of the stack, matched in hardness to the original so the wall can still dry.

Open the page

Chimney Rebuilds

Taking down failed brick and laying the stack again, with a new flue built in while the chimney stands open.

Open the page

Fireplace Cleaning

Room-side cleanup of ash, soot and door glass, leaving the firebox clear enough to spot cracks and gaps.

Open the page

Gas Fireplace Cleaning

Dust, lint and webs cleared from gas burners and pilots, with log placement, glass and the vent connection looked after.

Open the page

Gas Fireplace Repair

Fault finding on gas inserts, log sets and wall units that refuse to light, drop the pilot or burn with a dirty flame.

Open the page

Fireplace Remodel

New faces, hearths and mantels for an existing fireplace, planned around clearances and any insert or liner going in.

Open the page

Fireplace Inserts

Wood, gas and pellet inserts fitted to the opening, each vented through a stainless liner matched to the unit's collar.

Open the page

Pellet Stove Repair

Repairs for pellet stoves and inserts with feed, ignition or draft trouble, including the vent pipe they exhaust through.

Open the page

Wood Stove Repair

Gaskets, baffles, firebrick and the stovepipe or liner connection on wood stoves and inserts that smoke or burn poorly.

Open the page

Gas Logs

Vented log sets fitted to an open firebox, with the gas line, burner size and flue looked at before the first light.

Open the page

Chimney Seismic Retrofit

Reducing how much brick can fall from a chimney in a strong quake, with the method chosen after the flue and joints are seen.

Open the page

Chimney Crown Repair

Sealing or recasting the mortar top of a chimney so rain sheds off it and the flue tile can still expand.

Open the page

Dryer Vent Cleaning

Lint cleared from the duct between the dryer and the outside hood, with the run checked for crushed or loose sections.

Open the page

Chimney Leak Repair

Tracing where water enters at a chimney, then repairing that point, be it flashing, brick, crown, an open flue or the cap.

Open the page

Chimney Waterproofing

Breathable water repellent for porous brick, the last step once open joints and cracks at the top have been dealt with.

Open the page

Chimney Damper Repair

Rusted, warped or jammed throat dampers repaired or swapped, with a cable-run top damper as the option when the frame is gone.

Open the page

Chimney Chase Cover

Custom stainless tops for wood-framed chimney chases, cross-broken so rain runs off instead of pooling around the flue pipe.

Open the page

Pricing guides from Beckham Chimney Experts

Call (949) 879-2620