Professional chimney service
Beckham Chimney Experts

An Insert Matched to the Flue Above Your San Juan Capistrano Fireplace

Is This the Right Job?

Camera Stills in Every Report
Flue Faults Listed First
Written Quote Before Work
Based in San Juan Capistrano
Camera Stills in Every Report
Flue Faults Listed First
Written Quote Before Work
Based in San Juan Capistrano

What We Do on a Fireplace Inserts Job

An insert is only as good as the flue behind it. The existing tile gets filmed before any model is chosen, the opening is measured, and the stainless liner is matched to the collar of the unit you pick, so exhaust climbs fast and stays warm. Gas units placed in a working fireplace run $2,650 to $5,300 installed. Wood and pellet units are priced on paper once the measurements and footage are in.

Existing flue filmed before choosing a unit
Opening measured at the face and the back
Liner diameter matched to the unit collar
Surround panel closes the gap at the face
Gas line run and leak tested for gas units

Why We Look Up the Flue Before We Talk About Models

Every insert job we take on starts as a question about the flue, not the fireplace front. Most masonry chimneys around San Juan Capistrano were built for an open fire, so the clay tile column is wide: eight by twelve inches or larger is common. An insert breathes out through a much smaller collar, often six inches round. Push that small stream of exhaust into a big tile and it slows down, cools off and leaves water and creosote on the clay. That is why insert makers and NFPA 211 expect the unit to vent through its own liner, matched to the outlet and run the full height to the top. So before we open a brochure, we push a camera up the existing flue and record what is there. The footage shows offsets and bends, cracked or missing tiles, open mortar joints, glazed creosote and anything that has fallen in. Those images set the liner length, its shape and whether the chimney needs work before a new unit goes in.

The footage then narrows the choice of unit. Gas suits most homes we visit in south Orange County: steady heat, thermostat control, nothing to carry in from the side yard. It needs a gas line brought to the hearth and a vent pair or coaxial liner sized to the model. A wood insert throws the hottest fire and the sound of real logs, but it asks for dry fuel, ash removal and a sweep of the new liner every year. A pellet insert needs a wall outlet and a vent rated for pellets. When the unit is gas and the fireplace already works, our installed price sits at $2,650 to $5,300, and where it lands follows the model you pick, the liner length and the distance the gas line has to travel. A room with no chimney at all can still have a flame: a direct vent unit through an outside wall comes to $4,250 to $8,550 installed. Wood and pellet units get a written figure once the measuring visit is done.

Install Day, From the Smoke Chamber to the Crown

The throat of an older fireplace is usually too tight for a liner to pass while the cast damper plate hangs in it, so that plate comes out and the opening is trimmed where needed. The insert body is slid partway in so its collar sits under the smoke chamber. Up on the roof, the stainless tube is lowered through the tile column and guided past each bend the camera found earlier; a flexible liner can follow a gentle offset, and an oval section can pass a tile that is too narrow for round. At the bottom the liner is clamped to the collar with a connector made for that model. At the crown a stainless plate is cut to the tile, the liner is fastened through it and a rain cap with spark mesh goes on top. Where the old flue is close to framing, the liner is wrapped in insulation so it meets the clearance the maker lists. On gas units the supply joint gets a bubble test at every fitting, and only then is the trim frame closed up around the opening.

Before we pack up, the camera goes back down the new liner so we can check every joint and the connection at the collar with our own eyes, not by feel. Then we light the unit with you in the room, run it long enough for the draft to settle, and show you the controls, the blower switch and the shutoff. A wood insert gets a short talk about loading and air settings, since the way it burns in the first month sets the tone for the liner. You keep the paperwork for the unit and our notes on the liner size and length, which a future sweep or inspector will want. Inserts change how the chimney is used, so a yearly check of the liner and cap is part of the plan from day one. Homes in San Clemente and Laguna Niguel near the water also get a look at the cap and plate for salt wear on each visit.

How Beckham Chimney Experts Handles the Work

Flue Looked At First

We check the passage before quoting the fix

Stills You Can Keep

Camera frames go into the written report

Line by Line Prices

Each fix has its own figure on the quote

Film After the Work

Liners and rebuilds get a second camera pass

More from the service list

Chimney Sweep

Brushing and vacuuming a sooty flue, with the tile run noted so a later camera visit or liner job starts from facts.

Open the page

Chimney Inspection

Level 1 look at flue, crown, damper and firebox, answering whether the chimney suits the fire or appliance it serves.

Open the page

Chimney Repair

Fixes for the parts of a chimney that carry smoke and shed water, ordered from the flue outward.

Open the page

Fireplace Inspection

Room-side check of firebox, damper, hearth and surround, plus the opening sizes an insert or log set would need.

Open the page

Fireplace Repair

Firebox, damper and hearth work on masonry and factory-built units, so the fire burns where it should and smoke goes up.

Open the page

Chimney Level 2 Inspection

Recorded camera pass through the full flue, the level asked for at a sale, a fuel change, or after a quake or flue fire.

Open the page

Chimney Cap Installation

A fitted metal top with mesh sides, sized to one flue or the whole crown, keeping weather and animals out.

Open the page

Chimney Flashing Repair

New metal at the roof line where shingles or tile meet brick, lapped so rain runs past the chimney rather than into it.

Open the page

Chimney Masonry Repair

Brick and joint repair on the outside of the stack, matched in hardness to the original so the wall can still dry.

Open the page

Chimney Rebuilds

Taking down failed brick and laying the stack again, with a new flue built in while the chimney stands open.

Open the page

Fireplace Cleaning

Room-side cleanup of ash, soot and door glass, leaving the firebox clear enough to spot cracks and gaps.

Open the page

Gas Fireplace Cleaning

Dust, lint and webs cleared from gas burners and pilots, with log placement, glass and the vent connection looked after.

Open the page

Gas Fireplace Repair

Fault finding on gas inserts, log sets and wall units that refuse to light, drop the pilot or burn with a dirty flame.

Open the page

Fireplace Remodel

New faces, hearths and mantels for an existing fireplace, planned around clearances and any insert or liner going in.

Open the page

Pellet Stove Repair

Repairs for pellet stoves and inserts with feed, ignition or draft trouble, including the vent pipe they exhaust through.

Open the page

Wood Stove Repair

Gaskets, baffles, firebrick and the stovepipe or liner connection on wood stoves and inserts that smoke or burn poorly.

Open the page

Gas Logs

Vented log sets fitted to an open firebox, with the gas line, burner size and flue looked at before the first light.

Open the page

Chimney Seismic Retrofit

Reducing how much brick can fall from a chimney in a strong quake, with the method chosen after the flue and joints are seen.

Open the page

Chimney Crown Repair

Sealing or recasting the mortar top of a chimney so rain sheds off it and the flue tile can still expand.

Open the page

Dryer Vent Cleaning

Lint cleared from the duct between the dryer and the outside hood, with the run checked for crushed or loose sections.

Open the page

Chimney Liner Installation

Continuous stainless pipe inside a cracked or oversized clay flue, matched in diameter to the stove, insert or gas unit it serves.

Open the page

Chimney Leak Repair

Tracing where water enters at a chimney, then repairing that point, be it flashing, brick, crown, an open flue or the cap.

Open the page

Chimney Waterproofing

Breathable water repellent for porous brick, the last step once open joints and cracks at the top have been dealt with.

Open the page

Chimney Damper Repair

Rusted, warped or jammed throat dampers repaired or swapped, with a cable-run top damper as the option when the frame is gone.

Open the page

Chimney Chase Cover

Custom stainless tops for wood-framed chimney chases, cross-broken so rain runs off instead of pooling around the flue pipe.

Open the page

Pricing guides from Beckham Chimney Experts

Call (949) 879-2620